The relay contacts that the X-1A interlock will receive from
the X-1B interlock are:
| BENNO | EXPERIMENT B MASK ENABLE (normally open) |
| BENC | EXPERIMENT B MASK ENABLE (common) |
| A set of relay contacts that will form a closed circuit only when the X-1B branch line is in a configuration where it is safe to have beam present (i.e. no equipment can be damaged by beam power). | |
| BACNO | EXPERIMENT B ACTIVE (normally open) |
| BACC | EXPERIMENT B ACTIVE (common) |
| A set of relay contacts that will form a closed circuit when the X-1B branch line is in a configuration for taking beam (i.e., the X-1B mirrors are not fully retracted. For Operations Coordinator information. | |
It is expected that the X-1B beamline interlock will automatically close valves (and open contacts BENNO/BENC if necessary) to isolate the X-1B beamline vacuum system from the X-1B mirror chamber in case of poor vacuum in the X-1B beamline.
In addition, the X-1A interlock system is connected to
the pressure setpoint relay contacts on the G2 vacuum gauge controller.
Since G2 is located on the X-1B mirror chamber, X-1B supplies this
gauge and controller. The status of the G2 pressure setpoint relay
will be provided to X-1B as the contacts:
| G2NO | G2 normally open |
| G2C | G2 common |
| A set of relay contacts that are only closed when the G2 pressure is below the setpoint. | |