Front End Harness

The connections described above actually involve both the NSLS X-1 Front End interlock and the NSLS X-1 ``hutch'' interlock units. Therefore, a harness with two connectors H1 and H2 is provided to simplify cabling between these two units and the X-1A beamline interlock. In the description below, C15 and C16 refer to connectors on the X-1A interlock unit, while H1 and H2 refer to connectors on the harness for connection to cables leading to either the X-1 front end unit or the X-1 hutch unit, respectively. H1 is a 9 pin female connector with male pins, and H2 is a 16 pin female connector with male pins.

H1-1 C15-1 FEVNO Front end vacuum in (N.O. relay
H1-2 C15-2 FEVC closed by NSLS when pressure below set point)
H1-3 C15-3 MONO Mask open (N.O. relay closed
H1-4 C15-4 MOC by NSLS when mask not closed)
H1-9 C15-7 Shield Cable shield (Tied to AC ground at X-1A interlock unit)
       
H2-1 C15-5 ASNO Automatic shutter (N.O. relay
H2-2 C15-6 ASC closed by NSLS when in auto mode)
H2-3 C16-1 EMNO Enable mask (N.O. relay
H2-4 C16-2 EMC closed by X-1A when OK for mask open)
H2-5 C16-3 EMNC (N.C. relay open by X-1A when OK for mask open)
H2-6 C16-4 AACNO Branch line A active (N.O. relay
H2-7 C16-5 AACC closed by X-1A when X-1A active)
H2-8 C16-6 BACNO Branch line B active (N.O. relay
H2-9 C16-7 BACC closed by X-1A when X-1B active)
H2-10 C16-8 Shield Cable shield (Tied to AC ground at X-1A interlock unit)